{"id":463,"date":"2025-07-03T14:13:38","date_gmt":"2025-07-03T06:13:38","guid":{"rendered":"https:\/\/www.ampouletest.com\/?page_id=463"},"modified":"2026-02-02T08:15:39","modified_gmt":"2026-02-02T00:15:39","slug":"iso-8871-5","status":"publish","type":"page","link":"https:\/\/www.ampouletest.com\/da\/iso-8871-5","title":{"rendered":"ISO 8871-5"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"463\" class=\"elementor elementor-463\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c60fdbb e-flex e-con-boxed e-con e-parent\" data-id=\"c60fdbb\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-db6fcba e-con-full e-flex e-con e-child\" data-id=\"db6fcba\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-9d1f798 e-con-full e-flex e-con e-child\" data-id=\"9d1f798\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-8cc5a79 e-con-full e-flex e-con e-child\" data-id=\"8cc5a79\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b6b67d4 elementor-widget elementor-widget-heading\" data-id=\"b6b67d4\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ISO 8871-5<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5a032b0 elementor-widget elementor-widget-heading\" data-id=\"5a032b0\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test af elastomer lukning af ampuller<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c754e2a elementor-widget elementor-widget-text-editor\" data-id=\"c754e2a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"391\" data-end=\"1146\">I medicinalindustrien er det afg\u00f8rende for produktsikkerheden og -effektiviteten at sikre integriteten af emballagekomponenter som f.eks. elastomeriske lukninger. <strong data-start=\"562\" data-end=\"576\">ISO 8871-5<\/strong> beskriver <strong data-start=\"590\" data-end=\"654\">funktionskrav og testmetoder for gummipropper<\/strong> der anvendes med parenterale beholdere, is\u00e6r h\u00e6tteglas og ampuller. Denne standard d\u00e6kker forskellige testprocedurer, herunder <strong data-start=\"780\" data-end=\"822\">Test af gennemtr\u00e6ngelighed for gummipropper<\/strong>, <strong data-start=\"857\" data-end=\"878\">Test af ampullel\u00e6kage<\/strong>som <strong data-start=\"880\" data-end=\"911\">Testmetode for farvestofopl\u00f8snings t\u00e6thed<\/strong>, <strong data-start=\"913\" data-end=\"937\">Testmetode for selvforsegling<\/strong>og <strong data-start=\"943\" data-end=\"963\">Metode til test af vakuuml\u00e6kage<\/strong>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-69e503e elementor-button-align-stretch elementor-widget elementor-widget-form\" data-id=\"69e503e\" data-element_type=\"widget\" data-settings=\"{&quot;button_width&quot;:&quot;20&quot;,&quot;step_next_label&quot;:&quot;Next&quot;,&quot;step_previous_label&quot;:&quot;Previous&quot;,&quot;step_type&quot;:&quot;number_text&quot;,&quot;step_icon_shape&quot;:&quot;circle&quot;}\" data-widget_type=\"form.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<form class=\"elementor-form\" method=\"post\" name=\"New Form\" action=\"\">\n\t\t\t<input type=\"hidden\" name=\"post_id\" value=\"463\"\/>\n\t\t\t<input type=\"hidden\" name=\"form_id\" value=\"69e503e\"\/>\n\t\t\t<input type=\"hidden\" name=\"referer_title\" value=\"Ampoule Test\" \/>\n\n\t\t\t\n\t\t\t<div class=\"elementor-form-fields-wrapper elementor-labels-above\">\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-text elementor-field-group elementor-column elementor-field-group-name elementor-col-100 elementor-field-required\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-name\" class=\"elementor-field-label\">\n\t\t\t\t\t\t\t\tNavn\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<input size=\"1\" type=\"text\" name=\"form_fields[name]\" id=\"form-field-name\" class=\"elementor-field elementor-size-sm  elementor-field-textual\" placeholder=\"Navn\" required=\"required\" aria-required=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-text elementor-field-group elementor-column elementor-field-group-field_e89647e elementor-col-100\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-field_e89647e\" class=\"elementor-field-label\">\n\t\t\t\t\t\t\t\tVirksomhed\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<input size=\"1\" type=\"text\" name=\"form_fields[field_e89647e]\" id=\"form-field-field_e89647e\" class=\"elementor-field elementor-size-sm  elementor-field-textual\" placeholder=\"Virksomhed\">\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-email elementor-field-group elementor-column elementor-field-group-email elementor-col-100 elementor-field-required\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-email\" class=\"elementor-field-label\">\n\t\t\t\t\t\t\t\tE-mail\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<input size=\"1\" type=\"email\" name=\"form_fields[email]\" id=\"form-field-email\" class=\"elementor-field elementor-size-sm  elementor-field-textual\" placeholder=\"E-mail\" required=\"required\" aria-required=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-textarea elementor-field-group elementor-column elementor-field-group-message elementor-col-100\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-message\" class=\"elementor-field-label\">\n\t\t\t\t\t\t\t\tBesked\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t<textarea class=\"elementor-field-textual elementor-field  elementor-size-sm\" name=\"form_fields[message]\" id=\"form-field-message\" rows=\"4\" placeholder=\"Besked\"><\/textarea>\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-recaptcha_v3 elementor-field-group elementor-column elementor-field-group-field_5682c8b elementor-col-100 recaptcha_v3-bottomright\">\n\t\t\t\t\t<div class=\"elementor-field\" id=\"form-field-field_5682c8b\"><div class=\"elementor-g-recaptcha\" data-sitekey=\"6LeuX60rAAAAAElodUi54YrM7mqC6fGZX8tx93-Z\" data-type=\"v3\" data-action=\"Form\" data-badge=\"bottomright\" data-size=\"invisible\"><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-group elementor-column elementor-field-type-submit elementor-col-20 e-form__buttons\">\n\t\t\t\t\t<button class=\"elementor-button elementor-size-sm\" type=\"submit\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Send<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/button>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t<input type=\"hidden\" name=\"trp-form-language\" value=\"da\"\/><\/form>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-163fe1b e-con-full e-flex e-con e-child\" data-id=\"163fe1b\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f29ff9c e-flex e-con-boxed e-con e-parent\" data-id=\"f29ff9c\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fadf197 elementor-widget elementor-widget-heading\" data-id=\"fadf197\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Forst\u00e5else af ISO 8871-5<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7e073a9 elementor-widget elementor-widget-text-editor\" data-id=\"7e073a9\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1063\" data-end=\"1554\">ISO 8871-5 er en del af en serie, der fokuserer p\u00e5 elastomere dele beregnet til farmaceutisk brug. <strong data-start=\"1278\" data-end=\"1288\">Del 5<\/strong> henvender sig specifikt til <strong data-start=\"1316\" data-end=\"1368\">lukningernes funktionelle ydeevne og integritet<\/strong> der har forbindelse til injektionssystemer. M\u00e5let er at sikre, at lukninger tillader gennemtr\u00e6ngning med rimelig kraft, genforsegler efter punktering og forhindrer kontaminering eller l\u00e6kage under stressforhold.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fcfe601 e-flex e-con-boxed e-con e-parent\" data-id=\"fcfe601\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-285ac2f elementor-widget elementor-widget-heading\" data-id=\"285ac2f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test af gennemtr\u00e6ngelighed for gummipropper<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-030866f e-con-full e-flex e-con e-child\" data-id=\"030866f\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3c265f6 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"3c265f6\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.ampouletest.com\/da\/glass-grain-hydrolytic-resistance-tester-usp-iso\/\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"768\" height=\"1580\" src=\"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/Penetrability-Tester-for-Ampoule-Rubber-Stoppers-768x1580.webp\" class=\"attachment-medium_large size-medium_large wp-image-457\" alt=\"Test af gennemtr\u00e6ngelighed for ampulgummipropper\" srcset=\"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/Penetrability-Tester-for-Ampoule-Rubber-Stoppers-768x1580.webp 768w, https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/Penetrability-Tester-for-Ampoule-Rubber-Stoppers-146x300.webp 146w, https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/Penetrability-Tester-for-Ampoule-Rubber-Stoppers-498x1024.webp 498w, https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/Penetrability-Tester-for-Ampoule-Rubber-Stoppers-747x1536.webp 747w, https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/Penetrability-Tester-for-Ampoule-Rubber-Stoppers-995x2048.webp 995w, https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/Penetrability-Tester-for-Ampoule-Rubber-Stoppers-scaled.webp 1244w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Test af gennemtr\u00e6ngelighed<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a8ac35c e-con-full e-flex e-con e-child\" data-id=\"a8ac35c\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e3de559 elementor-widget elementor-widget-text-editor\" data-id=\"e3de559\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Den <strong data-start=\"1630\" data-end=\"1652\">Test af gennemtr\u00e6ngelighed<\/strong>defineret i <strong data-start=\"1665\" data-end=\"1676\">Bilag A<\/strong> af ISO 8871-5, evaluerer den kraft, der kr\u00e6ves for at gennembore en elastomer lukning ved hj\u00e6lp af en hypodermisk n\u00e5l.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a478b24 elementor-widget elementor-widget-heading\" data-id=\"a478b24\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Princip<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f528437 elementor-widget elementor-widget-text-editor\" data-id=\"f528437\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>En lukning testes under standardbetingelser for at m\u00e5le den maksimale kraft, der skal til, for at en n\u00e5l kan tr\u00e6nge igennem den. For stor gennemtr\u00e6ngningskraft kan kompromittere anvendeligheden og patientsikkerheden.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ab57be0 elementor-widget elementor-widget-heading\" data-id=\"ab57be0\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Testprocedure<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d7fbaf5 elementor-widget elementor-widget-text-editor\" data-id=\"d7fbaf5\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li data-start=\"2007\" data-end=\"2064\">S\u00e6t gummipropperne fast p\u00e5 h\u00e6tteglassene med krympepakninger.<\/li><li data-start=\"2067\" data-end=\"2169\">Udstyr en <strong data-start=\"2075\" data-end=\"2101\">Kraftm\u00e5leapparat<\/strong> som f.eks. <strong data-start=\"2114\" data-end=\"2141\">Cell Instruments NPT-01<\/strong> med en hypodermisk n\u00e5l.<\/li><li data-start=\"2172\" data-end=\"2209\">Stik vinkelret ind i proppen.<\/li><li data-start=\"2212\" data-end=\"2245\">Registrer den maksimale kraft, der kr\u00e6ves.<\/li><li data-start=\"2248\" data-end=\"2307\">Gentag med nye n\u00e5le p\u00e5 yderligere pr\u00f8ver (10 i alt).<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-72096bf elementor-widget elementor-widget-heading\" data-id=\"72096bf\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Betydning<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b451adc elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"b451adc\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Denne test simulerer den virkelige brug af <strong data-start=\"2370\" data-end=\"2390\">H\u00e6tteglas med flere doser<\/strong> og sikrer <strong data-start=\"2403\" data-end=\"2429\">let at administrere<\/strong> og samtidig bevare steriliteten.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-6d5e9de e-flex e-con-boxed e-con e-parent\" data-id=\"6d5e9de\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b64435d elementor-widget elementor-widget-heading\" data-id=\"b64435d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test af ampullel\u00e6kage med vakuum<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-59a8695 e-con-full e-flex e-con e-child\" data-id=\"59a8695\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-efb61d0 e-con-full e-flex e-con e-child\" data-id=\"efb61d0\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8e82f12 elementor-widget elementor-widget-heading\" data-id=\"8e82f12\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">T\u00e6thedstest af selvforsegling og farveopl\u00f8sning<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7d65f4e elementor-widget elementor-widget-text-editor\" data-id=\"7d65f4e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"2465\" data-end=\"2648\"><strong data-start=\"2516\" data-end=\"2527\">Bilag C<\/strong> af ISO 8871-5 beskriver en kombineret <strong data-start=\"2562\" data-end=\"2586\">Test af selvforsegling<\/strong> og <strong data-start=\"2591\" data-end=\"2622\">Test af farvestofopl\u00f8sningens t\u00e6thed<\/strong> efter gentagne punkteringer.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1394e99 elementor-widget elementor-widget-heading\" data-id=\"1394e99\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Princip<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ecccfe7 elementor-widget elementor-widget-text-editor\" data-id=\"ecccfe7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"2666\" data-end=\"2820\">Testen kontrollerer proppens evne til at genforsegle efter flere gennemtr\u00e6ngninger og modst\u00e5 l\u00e6kage, n\u00e5r den uds\u00e6ttes for vakuuminducerede trykforskelle.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-73c3270 elementor-widget elementor-widget-heading\" data-id=\"73c3270\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Testprocedure<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3b4d220 elementor-widget elementor-widget-text-editor\" data-id=\"3b4d220\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li data-start=\"2845\" data-end=\"2910\">Fyld 10 rene h\u00e6tteglas med partikelfrit vand til nominelt volumen.<\/li><li data-start=\"2913\" data-end=\"2953\">Forsegl med testlukningerne, og krymp.<\/li><li data-start=\"2956\" data-end=\"3016\">Stik 10 gange i hver lukning med en ny n\u00e5l hver gang.<\/li><li data-start=\"3019\" data-end=\"3071\">Neds\u00e6nk h\u00e6tteglassene i en opl\u00f8sning af methylenbl\u00e5t farvestof.<\/li><li data-start=\"3074\" data-end=\"3151\">P\u00e5f\u00f8r vakuum (-27 kPa) i 10 minutter, og vend derefter tilbage til atmosf\u00e6risk tryk.<\/li><li data-start=\"3154\" data-end=\"3217\">Lad det sidde i yderligere 30 minutter, skyl derefter og inspicer.<\/li><li data-start=\"3220\" data-end=\"3283\"><strong data-start=\"3220\" data-end=\"3282\">Enhver bl\u00e5 farve inde i h\u00e6tteglasset indikerer fejl i forseglingen.<\/strong>.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6c739f4 elementor-widget elementor-widget-heading\" data-id=\"6c739f4\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Ampullel\u00e6kagetest med farvestofopl\u00f8sning (bilag D)<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-183e820 elementor-widget elementor-widget-text-editor\" data-id=\"183e820\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3470\" data-end=\"3644\">Denne test vurderer specifikt <strong data-start=\"3559\" data-end=\"3595\">integritet i gr\u00e6nsefladen mellem lukning og hulrum<\/strong> under stressforhold uden forudg\u00e5ende punktering.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8f7dd3b elementor-widget elementor-widget-heading\" data-id=\"8f7dd3b\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Resum\u00e9 af proceduren<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-951cd8f elementor-widget elementor-widget-text-editor\" data-id=\"951cd8f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Fyld, forsegl og s\u00e6t l\u00e5g p\u00e5 h\u00e6tteglassene.<\/li><li>Fordyb dem i <strong data-start=\"3723\" data-end=\"3745\">Methylenbl\u00e5t farvestof<\/strong>.<\/li><li>Anvend vakuum og vedligehold i henhold til protokollen.<\/li><li>Unders\u00f8g for indtr\u00e6ngen af farvestof efter neds\u00e6nkning.<\/li><li><strong data-start=\"3846\" data-end=\"3886\">Tilstedev\u00e6relse af farvestof indeni indikerer en l\u00e6kage<\/strong>.<\/li><\/ul><p data-start=\"3889\" data-end=\"4030\">Denne test er afg\u00f8rende for <strong data-start=\"3915\" data-end=\"3946\">Protokoller for l\u00e6kagetest af ampuller<\/strong> hvor lukninger skal bevare steriliteten selv under transport- eller lagerstress.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f219514 elementor-widget elementor-widget-image\" data-id=\"f219514\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"461\" height=\"800\" src=\"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/07\/ampoule-leak-test.webp\" class=\"attachment-large size-large wp-image-468\" alt=\"iso 8871-5 ampullel\u00e6kagetest\" srcset=\"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/07\/ampoule-leak-test.webp 461w, https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/07\/ampoule-leak-test-173x300.webp 173w\" sizes=\"(max-width: 461px) 100vw, 461px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3abc6b6 e-flex e-con-boxed e-con e-parent\" data-id=\"3abc6b6\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5363c6b elementor-widget elementor-widget-heading\" data-id=\"5363c6b\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Hvorfor disse tests er vigtige<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bcd529d elementor-widget elementor-widget-text-editor\" data-id=\"bcd529d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li data-start=\"4068\" data-end=\"4136\"><strong data-start=\"4068\" data-end=\"4087\">Patientsikkerhed:<\/strong> Forhindrer kontaminering og doseringsvariationer.<\/li><li data-start=\"4139\" data-end=\"4219\"><strong data-start=\"4139\" data-end=\"4165\">Overholdelse af lovgivningen:<\/strong> Opfylder strenge farmaceutiske QA-krav.<\/li><li data-start=\"4222\" data-end=\"4298\"><strong data-start=\"4222\" data-end=\"4244\">Produktets integritet:<\/strong> Bevarer holdbarheden og den terapeutiske effektivitet.<\/li><\/ul><p data-start=\"4300\" data-end=\"4513\">Ved at udf\u00f8re <strong data-start=\"4318\" data-end=\"4360\">Test af gennemtr\u00e6ngelighed for gummipropper<\/strong>, <strong data-start=\"4362\" data-end=\"4386\">Test af selvforsegling<\/strong>og <strong data-start=\"4392\" data-end=\"4413\">Test af ampullel\u00e6kage<\/strong>opretholder producenterne standarder for <strong data-start=\"4450\" data-end=\"4482\">parenterale emballagesystemer<\/strong> som foreskrevet i <strong data-start=\"4498\" data-end=\"4512\">ISO 8871-5<\/strong>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b3187b9 e-flex e-con-boxed e-con e-parent\" data-id=\"b3187b9\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-17b575a elementor-widget elementor-widget-heading\" data-id=\"17b575a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Anbefalede instrumenter fra Cell Instruments<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3dd2ff8 elementor-widget elementor-widget-text-editor\" data-id=\"3dd2ff8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>For at sikre pr\u00e6cis og gentagelig testning tilbyder Cell Instruments avancerede, kompatible testl\u00f8sninger:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-11e44c2 e-grid e-con-full e-con e-child\" data-id=\"11e44c2\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-270d427 elementor-position-top elementor-widget elementor-widget-image-box\" data-id=\"270d427\" data-element_type=\"widget\" data-widget_type=\"image-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-image-box-wrapper\"><figure class=\"elementor-image-box-img\"><a href=\"https:\/\/www.ampouletest.com\/da\/penetrability-tester\/\" tabindex=\"-1\"><img decoding=\"async\" width=\"1244\" height=\"2560\" src=\"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/Penetrability-Tester-for-Ampoule-Rubber-Stoppers-scaled.webp\" class=\"attachment-full size-full wp-image-457\" alt=\"Test af gennemtr\u00e6ngelighed for ampulgummipropper\" srcset=\"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/Penetrability-Tester-for-Ampoule-Rubber-Stoppers-scaled.webp 1244w, https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/Penetrability-Tester-for-Ampoule-Rubber-Stoppers-146x300.webp 146w, https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/Penetrability-Tester-for-Ampoule-Rubber-Stoppers-498x1024.webp 498w, https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/Penetrability-Tester-for-Ampoule-Rubber-Stoppers-768x1580.webp 768w, https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/Penetrability-Tester-for-Ampoule-Rubber-Stoppers-747x1536.webp 747w, https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/Penetrability-Tester-for-Ampoule-Rubber-Stoppers-995x2048.webp 995w\" sizes=\"(max-width: 1244px) 100vw, 1244px\" \/><\/a><\/figure><div class=\"elementor-image-box-content\"><h3 class=\"elementor-image-box-title\"><a href=\"https:\/\/www.ampouletest.com\/da\/penetrability-tester\/\">NPT-01 gennemtr\u00e6ngelighedstester<\/a><\/h3><p class=\"elementor-image-box-description\">Optimeret til analyse af indtr\u00e6ngningskraft i elastomeriske lukninger.<\/p><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d9d79aa elementor-position-top elementor-widget elementor-widget-image-box\" data-id=\"d9d79aa\" data-element_type=\"widget\" data-widget_type=\"image-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-image-box-wrapper\"><figure class=\"elementor-image-box-img\"><img loading=\"lazy\" decoding=\"async\" width=\"461\" height=\"800\" src=\"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/07\/ampoule-leak-test.webp\" class=\"attachment-full size-full wp-image-468\" alt=\"iso 8871-5 ampullel\u00e6kagetest\" srcset=\"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/07\/ampoule-leak-test.webp 461w, https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/07\/ampoule-leak-test-173x300.webp 173w\" sizes=\"(max-width: 461px) 100vw, 461px\" \/><\/figure><div class=\"elementor-image-box-content\"><h3 class=\"elementor-image-box-title\">LT-03 Vakuum-l\u00e6kagetester<\/h3><p class=\"elementor-image-box-description\">Ideel til at udf\u00f8re vakuumassisteret farveindtr\u00e6ngningstest.<\/p><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ISO 8871-5 Ampoule Elastomeric Closure Testing In the pharmaceutical industry, ensuring the integrity of packaging components such as elastomeric closures is critical to product safety and efficacy. ISO 8871-5 outlines the functional requirements and test methods for rubber stoppers used with parenteral containers, particularly vials and ampoules. This standard covers various test procedures including the [&hellip;]<\/p>","protected":false},"author":3,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-463","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.2 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>ISO 8871-5 Ampoule Rubber Stopper Test - Penetrability, Leak Test<\/title>\n<meta name=\"description\" content=\"ISO 8871-5 testing for ampoule elastomeric closures. Penetrability, self-sealing, dye solution leak test for ampoule rubber stoppers.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ampouletest.com\/da\/iso-8871-5\/\" \/>\n<meta property=\"og:locale\" content=\"da_DK\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ISO 8871-5 Ampoule Rubber Stopper Test - Penetrability, Leak Test\" \/>\n<meta property=\"og:description\" content=\"ISO 8871-5 testing for ampoule elastomeric closures. Penetrability, self-sealing, dye solution leak test for ampoule rubber stoppers.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ampouletest.com\/da\/iso-8871-5\/\" \/>\n<meta property=\"og:site_name\" content=\"Ampoule Test\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-02T00:15:39+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/Penetrability-Tester-for-Ampoule-Rubber-Stoppers-scaled.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1244\" \/>\n\t<meta property=\"og:image:height\" content=\"2560\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.ampouletest.com\/iso-8871-5\",\"url\":\"https:\/\/www.ampouletest.com\/iso-8871-5\",\"name\":\"ISO 8871-5 Ampoule Rubber Stopper Test - Penetrability, Leak Test\",\"isPartOf\":{\"@id\":\"https:\/\/www.ampouletest.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.ampouletest.com\/iso-8871-5#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.ampouletest.com\/iso-8871-5#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/Penetrability-Tester-for-Ampoule-Rubber-Stoppers-768x1580.webp\",\"datePublished\":\"2025-07-03T06:13:38+00:00\",\"dateModified\":\"2026-02-02T00:15:39+00:00\",\"description\":\"ISO 8871-5 testing for ampoule elastomeric closures. Penetrability, self-sealing, dye solution leak test for ampoule rubber stoppers.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.ampouletest.com\/iso-8871-5#breadcrumb\"},\"inLanguage\":\"da-DK\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.ampouletest.com\/iso-8871-5\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"da-DK\",\"@id\":\"https:\/\/www.ampouletest.com\/iso-8871-5#primaryimage\",\"url\":\"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/Penetrability-Tester-for-Ampoule-Rubber-Stoppers-768x1580.webp\",\"contentUrl\":\"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/Penetrability-Tester-for-Ampoule-Rubber-Stoppers-768x1580.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.ampouletest.com\/iso-8871-5#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.ampouletest.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"ISO 8871-5\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.ampouletest.com\/#website\",\"url\":\"https:\/\/www.ampouletest.com\/\",\"name\":\"Softgel Test\",\"description\":\"Ampoule Test Solutions\",\"publisher\":{\"@id\":\"https:\/\/www.ampouletest.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.ampouletest.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"da-DK\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.ampouletest.com\/#organization\",\"name\":\"Softgel Test\",\"url\":\"https:\/\/www.ampouletest.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"da-DK\",\"@id\":\"https:\/\/www.ampouletest.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/01\/Softgel-Test-Logo.webp\",\"contentUrl\":\"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/01\/Softgel-Test-Logo.webp\",\"width\":836,\"height\":238,\"caption\":\"Softgel Test\"},\"image\":{\"@id\":\"https:\/\/www.ampouletest.com\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ISO 8871-5 Ampoule Rubber Stopper Test - Penetrability, Leak Test","description":"ISO 8871-5 testing for ampoule elastomeric closures. Penetrability, self-sealing, dye solution leak test for ampoule rubber stoppers.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ampouletest.com\/da\/iso-8871-5\/","og_locale":"da_DK","og_type":"article","og_title":"ISO 8871-5 Ampoule Rubber Stopper Test - Penetrability, Leak Test","og_description":"ISO 8871-5 testing for ampoule elastomeric closures. Penetrability, self-sealing, dye solution leak test for ampoule rubber stoppers.","og_url":"https:\/\/www.ampouletest.com\/da\/iso-8871-5\/","og_site_name":"Ampoule Test","article_modified_time":"2026-02-02T00:15:39+00:00","og_image":[{"width":1244,"height":2560,"url":"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/Penetrability-Tester-for-Ampoule-Rubber-Stoppers-scaled.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.ampouletest.com\/iso-8871-5","url":"https:\/\/www.ampouletest.com\/iso-8871-5","name":"ISO 8871-5 Ampoule Rubber Stopper Test - Penetrability, Leak Test","isPartOf":{"@id":"https:\/\/www.ampouletest.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.ampouletest.com\/iso-8871-5#primaryimage"},"image":{"@id":"https:\/\/www.ampouletest.com\/iso-8871-5#primaryimage"},"thumbnailUrl":"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/Penetrability-Tester-for-Ampoule-Rubber-Stoppers-768x1580.webp","datePublished":"2025-07-03T06:13:38+00:00","dateModified":"2026-02-02T00:15:39+00:00","description":"ISO 8871-5 testing for ampoule elastomeric closures. Penetrability, self-sealing, dye solution leak test for ampoule rubber stoppers.","breadcrumb":{"@id":"https:\/\/www.ampouletest.com\/iso-8871-5#breadcrumb"},"inLanguage":"da-DK","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ampouletest.com\/iso-8871-5"]}]},{"@type":"ImageObject","inLanguage":"da-DK","@id":"https:\/\/www.ampouletest.com\/iso-8871-5#primaryimage","url":"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/Penetrability-Tester-for-Ampoule-Rubber-Stoppers-768x1580.webp","contentUrl":"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/Penetrability-Tester-for-Ampoule-Rubber-Stoppers-768x1580.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/www.ampouletest.com\/iso-8871-5#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.ampouletest.com\/"},{"@type":"ListItem","position":2,"name":"ISO 8871-5"}]},{"@type":"WebSite","@id":"https:\/\/www.ampouletest.com\/#website","url":"https:\/\/www.ampouletest.com\/","name":"Softgel Test","description":"Ampoule Test Solutions","publisher":{"@id":"https:\/\/www.ampouletest.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.ampouletest.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"da-DK"},{"@type":"Organization","@id":"https:\/\/www.ampouletest.com\/#organization","name":"Softgel Test","url":"https:\/\/www.ampouletest.com\/","logo":{"@type":"ImageObject","inLanguage":"da-DK","@id":"https:\/\/www.ampouletest.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/01\/Softgel-Test-Logo.webp","contentUrl":"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/01\/Softgel-Test-Logo.webp","width":836,"height":238,"caption":"Softgel Test"},"image":{"@id":"https:\/\/www.ampouletest.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.ampouletest.com\/da\/wp-json\/wp\/v2\/pages\/463","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ampouletest.com\/da\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.ampouletest.com\/da\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.ampouletest.com\/da\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ampouletest.com\/da\/wp-json\/wp\/v2\/comments?post=463"}],"version-history":[{"count":5,"href":"https:\/\/www.ampouletest.com\/da\/wp-json\/wp\/v2\/pages\/463\/revisions"}],"predecessor-version":[{"id":671,"href":"https:\/\/www.ampouletest.com\/da\/wp-json\/wp\/v2\/pages\/463\/revisions\/671"}],"wp:attachment":[{"href":"https:\/\/www.ampouletest.com\/da\/wp-json\/wp\/v2\/media?parent=463"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}