{"id":433,"date":"2025-06-17T15:40:00","date_gmt":"2025-06-17T07:40:00","guid":{"rendered":"https:\/\/www.ampouletest.com\/?page_id=433"},"modified":"2026-02-02T08:15:34","modified_gmt":"2026-02-02T00:15:34","slug":"iso-720-hydrolytic-resistance-of-glass-containers","status":"publish","type":"page","link":"https:\/\/www.ampouletest.com\/sl\/iso-720-hydrolytic-resistance-of-glass-containers","title":{"rendered":"ISO 720"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"433\" class=\"elementor elementor-433\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c60fdbb e-flex e-con-boxed e-con e-parent\" data-id=\"c60fdbb\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-db6fcba e-con-full e-flex e-con e-child\" data-id=\"db6fcba\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-9d1f798 e-con-full e-flex e-con e-child\" data-id=\"9d1f798\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-8cc5a79 e-con-full e-flex e-con e-child\" data-id=\"8cc5a79\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b6b67d4 elementor-widget elementor-widget-heading\" data-id=\"b6b67d4\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ISO 720 Hidroliti\u010dna odpornost<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5a032b0 elementor-widget elementor-widget-heading\" data-id=\"5a032b0\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">steklene ampule<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c754e2a elementor-widget elementor-widget-text-editor\" data-id=\"c754e2a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"309\" data-end=\"787\">Spletna stran <strong data-start=\"428\" data-end=\"439\">ISO 720<\/strong> standard opisuje kriti\u010dno metodo za ocenjevanje <strong data-start=\"495\" data-end=\"540\">hidrolitska odpornost steklenih posod<\/strong>, zlasti tiste, ki se uporabljajo v farmacevtski embala\u017ei, kot so <strong data-start=\"597\" data-end=\"615\">steklene ampule<\/strong>. Ta preskus zagotavlja, da se kemijska stabilnost stekla ohrani pri izpostavljenosti visokim temperaturam in vodi ter tako ohranja celovitost in varnost farmacevtskih izdelkov.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-69e503e elementor-button-align-stretch elementor-widget elementor-widget-form\" data-id=\"69e503e\" data-element_type=\"widget\" data-settings=\"{&quot;button_width&quot;:&quot;20&quot;,&quot;step_next_label&quot;:&quot;Next&quot;,&quot;step_previous_label&quot;:&quot;Previous&quot;,&quot;step_type&quot;:&quot;number_text&quot;,&quot;step_icon_shape&quot;:&quot;circle&quot;}\" data-widget_type=\"form.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<form class=\"elementor-form\" method=\"post\" name=\"New Form\" action=\"\">\n\t\t\t<input type=\"hidden\" name=\"post_id\" value=\"433\"\/>\n\t\t\t<input type=\"hidden\" name=\"form_id\" value=\"69e503e\"\/>\n\t\t\t<input type=\"hidden\" name=\"referer_title\" value=\"Ampoule Test\" \/>\n\n\t\t\t\n\t\t\t<div class=\"elementor-form-fields-wrapper elementor-labels-above\">\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-text elementor-field-group elementor-column elementor-field-group-name elementor-col-100 elementor-field-required\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-name\" class=\"elementor-field-label\">\n\t\t\t\t\t\t\t\tIme\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<input size=\"1\" type=\"text\" name=\"form_fields[name]\" id=\"form-field-name\" class=\"elementor-field elementor-size-sm  elementor-field-textual\" placeholder=\"Ime\" required=\"required\" aria-required=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-text elementor-field-group elementor-column elementor-field-group-field_07115be elementor-col-100\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-field_07115be\" class=\"elementor-field-label\">\n\t\t\t\t\t\t\t\tPodjetje\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<input size=\"1\" type=\"text\" name=\"form_fields[field_07115be]\" id=\"form-field-field_07115be\" class=\"elementor-field elementor-size-sm  elementor-field-textual\" placeholder=\"Podjetje\">\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-email elementor-field-group elementor-column elementor-field-group-email elementor-col-100 elementor-field-required\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-email\" class=\"elementor-field-label\">\n\t\t\t\t\t\t\t\tE-po\u0161ta\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<input size=\"1\" type=\"email\" name=\"form_fields[email]\" id=\"form-field-email\" class=\"elementor-field elementor-size-sm  elementor-field-textual\" placeholder=\"E-po\u0161ta\" required=\"required\" aria-required=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-textarea elementor-field-group elementor-column elementor-field-group-message elementor-col-100\">\n\t\t\t\t\t\t\t\t\t\t\t\t<label for=\"form-field-message\" class=\"elementor-field-label\">\n\t\t\t\t\t\t\t\tSporo\u010dilo\t\t\t\t\t\t\t<\/label>\n\t\t\t\t\t\t<textarea class=\"elementor-field-textual elementor-field  elementor-size-sm\" name=\"form_fields[message]\" id=\"form-field-message\" rows=\"4\" placeholder=\"Sporo\u010dilo\"><\/textarea>\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-type-recaptcha_v3 elementor-field-group elementor-column elementor-field-group-field_ef845c1 elementor-col-100 recaptcha_v3-bottomright\">\n\t\t\t\t\t<div class=\"elementor-field\" id=\"form-field-field_ef845c1\"><div class=\"elementor-g-recaptcha\" data-sitekey=\"6LeuX60rAAAAAElodUi54YrM7mqC6fGZX8tx93-Z\" data-type=\"v3\" data-action=\"Form\" data-badge=\"bottomright\" data-size=\"invisible\"><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"elementor-field-group elementor-column elementor-field-type-submit elementor-col-20 e-form__buttons\">\n\t\t\t\t\t<button class=\"elementor-button elementor-size-sm\" type=\"submit\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Po\u0161lji<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/button>\n\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t<input type=\"hidden\" name=\"trp-form-language\" value=\"sl\"\/><\/form>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-163fe1b e-con-full e-flex e-con e-child\" data-id=\"163fe1b\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f29ff9c e-flex e-con-boxed e-con e-parent\" data-id=\"f29ff9c\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fadf197 elementor-widget elementor-widget-heading\" data-id=\"fadf197\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Razumevanje standarda ISO 720 in njegovega pomena v farmacevtski industriji<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7e073a9 elementor-widget elementor-widget-text-editor\" data-id=\"7e073a9\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1063\" data-end=\"1554\">Spletna stran <strong data-start=\"1145\" data-end=\"1161\">ISO 720:2020<\/strong> standard z naslovom <em data-start=\"1179\" data-end=\"1272\">Steklo - Hidroliti\u010dna odpornost steklenih zrn pri 121 \u00b0C - Preskusna metoda in klasifikacija<\/em>zagotavlja metodo za dolo\u010danje koli\u010dine alkalnega materiala, ki ga steklo spro\u0161\u010da pod nadzorovanimi pogoji. To je bistvenega pomena za farmacevtske proizvajalce, ki se zana\u0161ajo na <strong data-start=\"1442\" data-end=\"1460\">steklene ampule<\/strong> in viale za varno shranjevanje zdravil za injiciranje, peroralnih raztopin in drugih pomembnih zdravil.<\/p><p data-start=\"1556\" data-end=\"1782\">Farmacevtska steklena embala\u017ea, ki v svojo vsebino spro\u0161\u010da prese\u017eek alkalij, lahko spremeni sestavo zdravila, kar predstavlja tveganje za varnost pacientov. Zato je standard ISO 720 temeljno merilo za kakovost materialov in skladnost s predpisi.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fcfe601 e-flex e-con-boxed e-con e-parent\" data-id=\"fcfe601\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-285ac2f elementor-widget elementor-widget-heading\" data-id=\"285ac2f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Hidroliti\u010dna odpornost steklenih posod: Osnovna na\u010dela<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-030866f e-con-full e-flex e-con e-child\" data-id=\"030866f\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3c265f6 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"3c265f6\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.ampouletest.com\/sl\/glass-grain-hydrolytic-resistance-tester-usp-iso\/\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/ISO-720-Hydrolytic-Resistance-of-Glass-Ampoule-1.webp\" class=\"attachment-full size-full wp-image-442\" alt=\"ISO 720 Hidroliti\u010dna odpornost steklene ampule\" srcset=\"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/ISO-720-Hydrolytic-Resistance-of-Glass-Ampoule-1.webp 600w, https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/ISO-720-Hydrolytic-Resistance-of-Glass-Ampoule-1-300x300.webp 300w, https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/ISO-720-Hydrolytic-Resistance-of-Glass-Ampoule-1-150x150.webp 150w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Test steklenih zrn<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a8ac35c e-con-full e-flex e-con e-child\" data-id=\"a8ac35c\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b451adc elementor-widget__width-inherit elementor-widget elementor-widget-text-editor\" data-id=\"b451adc\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"1789\" data-end=\"2028\"><strong data-start=\"1854\" data-end=\"1899\">Hidroliti\u010dna odpornost steklenih posod<\/strong> se nana\u0161a na sposobnost materiala, da prenese kemi\u010dne napade vode pri povi\u0161anih temperaturah. Postopek ISO 720 vklju\u010duje:<\/p><ul><li data-start=\"2032\" data-end=\"2109\"><strong data-start=\"2032\" data-end=\"2056\">Drobljenje in presejanje<\/strong> steklenih vzorcev do dolo\u010dene velikosti zrn (300-425 \u03bcm).<\/li><li data-start=\"2112\" data-end=\"2202\"><strong data-start=\"2112\" data-end=\"2133\">Pridobivanje alkalij<\/strong> s segrevanjem zrn v <strong data-start=\"2159\" data-end=\"2186\">voda razreda 2 pri 121 \u00b0C<\/strong> 30 minut.<\/li><li data-start=\"2205\" data-end=\"2294\"><strong data-start=\"2205\" data-end=\"2241\">Titriranje ekstrahirane raztopine<\/strong> s klorovodikovo kislino z uporabo metil rde\u010dega indikatorja.<\/li><\/ul><p data-start=\"2296\" data-end=\"2461\">Koli\u010dina porabljene kisline med titracijo dolo\u010da odpornost stekla. Ve\u010dja poraba kisline pomeni ve\u010dje spro\u0161\u010danje alkalij, kar pomeni manj\u0161o odpornost.<\/p><p data-start=\"2463\" data-end=\"2623\">Ta preskus je klju\u010dnega pomena za ampule, viale in steklenice iz natrijevega ali borosilikatnega stekla, ki se pogosto uporabljajo v sterilni farmacevtski embala\u017ei.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cbab5bf elementor-widget elementor-widget-heading\" data-id=\"cbab5bf\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Testiranje steklenih ampul v skladu s standardom ISO 720<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-17a8f0b elementor-widget elementor-widget-text-editor\" data-id=\"17a8f0b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"2630\" data-end=\"2896\"><strong data-start=\"2680\" data-end=\"2706\">Testiranje steklenih ampul<\/strong> v skladu s standardom ISO 720 ne gre le za uspe\u0161no opravljen preskus kemijske obstojnosti, temve\u010d za zagotavljanje skladnosti, varnosti izdelkov in za\u0161\u010dite kon\u010dnih uporabnikov. Tukaj je kratka raz\u010dlenitev klju\u010dnih faz preskusa:<\/p><ul><li data-start=\"2900\" data-end=\"3021\"><strong data-start=\"2900\" data-end=\"2923\">Priprava vzorca:<\/strong> Zagotovite ustrezno \u017earjenje. Steklene vzorce zavijte, zdrobite in presejte, da dose\u017eete dolo\u010deno velikost.<\/li><li data-start=\"3024\" data-end=\"3138\"><strong data-start=\"3024\" data-end=\"3048\">Ultrazvo\u010dno \u010di\u0161\u010denje:<\/strong> Z acetonom in ultrazvo\u010dnimi valovi temeljito o\u010distite steklena zrna in odstranite ne\u010disto\u010de.<\/li><li data-start=\"3141\" data-end=\"3210\"><strong data-start=\"3141\" data-end=\"3152\">Su\u0161enje:<\/strong> Su\u0161ite pri 140 \u00b0C 20 minut, da odstranite preostalo vlago.<\/li><li data-start=\"3213\" data-end=\"3300\"><strong data-start=\"3213\" data-end=\"3229\">Avtoklaviranje:<\/strong> Vzorce podvr\u017eite nadzorovanemu temperaturnemu ciklu, ki dose\u017ee 121 \u00b0C.<\/li><li data-start=\"3303\" data-end=\"3437\"><strong data-start=\"3303\" data-end=\"3332\">Titracija in vrednotenje:<\/strong> Izmerite koli\u010dino kisline, ki je potrebna za nevtralizacijo raztopine ekstrakta, in ustrezno razvrstite steklo.<\/li><\/ul><p data-start=\"3439\" data-end=\"3558\">Da bi zagotovili ponovljivost in natan\u010dnost, ta test zahteva natan\u010dno ravnanje in zanesljivo opremo za pripravo vzorca.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-6d5e9de e-flex e-con-boxed e-con e-parent\" data-id=\"6d5e9de\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8e82f12 elementor-widget elementor-widget-heading\" data-id=\"8e82f12\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Avtomatizirana podpora z merilnikom hidrolitske odpornosti steklenih zrn GHR-01A<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7d65f4e elementor-widget elementor-widget-text-editor\" data-id=\"7d65f4e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"3565\" data-end=\"3887\">Celi\u010dni instrumenti' <strong data-start=\"3665\" data-end=\"3676\">GHR-01A<\/strong> je zasnovan za avtomatizacijo in optimizacijo priprave steklenih zrn za testiranje po ISO 720 in ISO 719. Njegove inteligentne funkcije poenostavijo najzahtevnej\u0161e faze preskusa - drobljenje, presejanje in varno ravnanje.<\/p><p data-start=\"3889\" data-end=\"3919\"><strong data-start=\"3889\" data-end=\"3919\">Glavne prednosti GHR-01A:<\/strong><\/p><ul><li data-start=\"3923\" data-end=\"4018\"><strong data-start=\"3923\" data-end=\"3955\">Avtomatizirano drobljenje in presejanje<\/strong>: Zagotavlja enakomerno velikost delcev z minimalnim ro\u010dnim delom.<\/li><li data-start=\"4021\" data-end=\"4090\"><strong data-start=\"4021\" data-end=\"4042\">Natan\u010den nadzor<\/strong>: Zmanj\u0161a variabilnost, izbolj\u0161a natan\u010dnost vzorca.<\/li><li data-start=\"4093\" data-end=\"4170\"><strong data-start=\"4093\" data-end=\"4112\">Pove\u010dana varnost<\/strong>: Za\u0161\u010ditni elementi varujejo uporabnike pred razbitinami stekla.<\/li><li data-start=\"4173\" data-end=\"4257\"><strong data-start=\"4173\" data-end=\"4196\">Okolju prijazno oblikovanje<\/strong>: odgovorno zbira odpadke in zmanj\u0161uje tveganje onesna\u017eenja.<\/li><li data-start=\"4260\" data-end=\"4327\"><strong data-start=\"4260\" data-end=\"4287\">Uporabniku prijazen vmesnik<\/strong>: Intuitivno upravljanje prek zaslona HMI.<\/li><\/ul><p data-start=\"4329\" data-end=\"4512\">GHR-01A z avtomatizacijo klju\u010dnih korakov zagotavlja ponovljive in visokokakovostne rezultate, zato je dragocen pripomo\u010dek za farmacevtske laboratorije in proizvajalce embala\u017ee, ki si prizadevajo za skladnost s standardi ISO.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-bbe91e5 e-flex e-con-boxed e-con e-parent\" data-id=\"bbe91e5\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6c739f4 elementor-widget elementor-widget-heading\" data-id=\"6c739f4\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Najbolj\u0161e prakse za izvajanje presku\u0161anja ISO 720<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-183e820 elementor-widget elementor-widget-text-editor\" data-id=\"183e820\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"4519\" data-end=\"4643\">\u010ce \u017eelite dose\u010di to\u010dne in skladne rezultate, upo\u0161tevajte ta priporo\u010dila:<\/p><ol><li data-start=\"4648\" data-end=\"4722\"><strong data-start=\"4648\" data-end=\"4676\">Preverjanje kakovosti \u017earjenja<\/strong>: Slabo \u017earjeno steklo lahko popa\u010di rezultate preskusa.<\/li><li data-start=\"4726\" data-end=\"4806\"><strong data-start=\"4726\" data-end=\"4748\">Velikost kontrolnega zrna<\/strong>: Za veljavne podatke poskrbite, da so delci veliki od 300 do 425 \u03bcm.<\/li><li data-start=\"4810\" data-end=\"4900\"><strong data-start=\"4810\" data-end=\"4833\">Izogibajte se kontaminaciji<\/strong>: Uporabljajte \u010disto opremo in sve\u017ee reagente; z vzorci ravnajte previdno.<\/li><li data-start=\"4904\" data-end=\"4989\"><strong data-start=\"4904\" data-end=\"4932\">Pravo\u010dasno izvedite titracijo<\/strong>: Kemi\u010dno analizo opravite v eni uri po segrevanju.<\/li><li data-start=\"4993\" data-end=\"5079\"><strong data-start=\"4993\" data-end=\"5021\">Uporaba umerjene opreme<\/strong>: Klju\u010dnega pomena so natan\u010dne termo\u010dlene in titracijske nastavitve.<\/li><\/ol><p data-start=\"5081\" data-end=\"5217\">Pravilno izvajanje standarda ISO 720 pomaga proizvajalcem ohranjati stabilnost izdelkov, dosegati skladnost s predpisi in zagotavljati zaupanje strank.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3abc6b6 e-flex e-con-boxed e-con e-parent\" data-id=\"3abc6b6\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5363c6b elementor-widget elementor-widget-heading\" data-id=\"5363c6b\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Zakaj je ISO 720 pomemben za strokovnjake za nadzor kakovosti<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bcd529d elementor-widget elementor-widget-text-editor\" data-id=\"bcd529d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"5224\" data-end=\"5441\">Za strokovnjake na podro\u010dju farmacevtske embala\u017ee in zagotavljanja kakovosti je ISO 720 znanstveno potrjena metoda za ocenjevanje u\u010dinkovitosti stekla. Pomaga pri:<\/p><ul><li data-start=\"5445\" data-end=\"5498\">Razvrstite steklo v kategorije hidrolitske odpornosti.<\/li><li data-start=\"5501\" data-end=\"5549\">Podpora pri izbiri materiala za zadr\u017eevanje zdravil.<\/li><li data-start=\"5552\" data-end=\"5610\">Prepre\u010devanje kemi\u010dnih interakcij, ki ogro\u017eajo varnost zdravil.<\/li><li data-start=\"5613\" data-end=\"5662\">Zagotavljanje skladnosti z mednarodnimi standardi.<\/li><\/ul><p data-start=\"5664\" data-end=\"5793\">Testiranje <strong data-start=\"5676\" data-end=\"5721\">hidrolitska odpornost steklenih posod<\/strong> ni le laboratorijski postopek, temve\u010d tudi nadzornik kakovosti na podro\u010dju javnega zdravja.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ISO 720 Hydrolytic Resistance of Glass Ampoule The ISO 720 standard outlines a critical method for evaluating the hydrolytic resistance of glass containers, especially those used in pharmaceutical packaging like glass ampoules. This test ensures that the chemical stability of glass is maintained when exposed to high temperatures and water, preserving the integrity and safety [&hellip;]<\/p>","protected":false},"author":3,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-433","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.2 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>ISO 720 Hydrolytic Resistance of Glass Containers\/Ampoule<\/title>\n<meta name=\"description\" content=\"ISO 720 for hydrolytic resistance of glass containers. Learn how Cell Instruments\u2019 GHR-01A ensures accurate, compliant results.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ampouletest.com\/sl\/iso-720-hydrolytic-resistance-of-glass-containers\/\" \/>\n<meta property=\"og:locale\" content=\"sl_SI\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ISO 720 Hydrolytic Resistance of Glass Containers\/Ampoule\" \/>\n<meta property=\"og:description\" content=\"ISO 720 for hydrolytic resistance of glass containers. Learn how Cell Instruments\u2019 GHR-01A ensures accurate, compliant results.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ampouletest.com\/sl\/iso-720-hydrolytic-resistance-of-glass-containers\/\" \/>\n<meta property=\"og:site_name\" content=\"Ampoule Test\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-02T00:15:34+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/ISO-720-Hydrolytic-Resistance-of-Glass-Ampoule-1.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.ampouletest.com\/iso-720-hydrolytic-resistance-of-glass-containers\",\"url\":\"https:\/\/www.ampouletest.com\/iso-720-hydrolytic-resistance-of-glass-containers\",\"name\":\"ISO 720 Hydrolytic Resistance of Glass Containers\/Ampoule\",\"isPartOf\":{\"@id\":\"https:\/\/www.ampouletest.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.ampouletest.com\/iso-720-hydrolytic-resistance-of-glass-containers#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.ampouletest.com\/iso-720-hydrolytic-resistance-of-glass-containers#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/ISO-720-Hydrolytic-Resistance-of-Glass-Ampoule-1.webp\",\"datePublished\":\"2025-06-17T07:40:00+00:00\",\"dateModified\":\"2026-02-02T00:15:34+00:00\",\"description\":\"ISO 720 for hydrolytic resistance of glass containers. Learn how Cell Instruments\u2019 GHR-01A ensures accurate, compliant results.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.ampouletest.com\/iso-720-hydrolytic-resistance-of-glass-containers#breadcrumb\"},\"inLanguage\":\"sl-SI\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.ampouletest.com\/iso-720-hydrolytic-resistance-of-glass-containers\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"sl-SI\",\"@id\":\"https:\/\/www.ampouletest.com\/iso-720-hydrolytic-resistance-of-glass-containers#primaryimage\",\"url\":\"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/ISO-720-Hydrolytic-Resistance-of-Glass-Ampoule-1.webp\",\"contentUrl\":\"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/ISO-720-Hydrolytic-Resistance-of-Glass-Ampoule-1.webp\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.ampouletest.com\/iso-720-hydrolytic-resistance-of-glass-containers#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.ampouletest.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"ISO 720\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.ampouletest.com\/#website\",\"url\":\"https:\/\/www.ampouletest.com\/\",\"name\":\"Softgel Test\",\"description\":\"Ampoule Test Solutions\",\"publisher\":{\"@id\":\"https:\/\/www.ampouletest.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.ampouletest.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"sl-SI\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.ampouletest.com\/#organization\",\"name\":\"Softgel Test\",\"url\":\"https:\/\/www.ampouletest.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"sl-SI\",\"@id\":\"https:\/\/www.ampouletest.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/01\/Softgel-Test-Logo.webp\",\"contentUrl\":\"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/01\/Softgel-Test-Logo.webp\",\"width\":836,\"height\":238,\"caption\":\"Softgel Test\"},\"image\":{\"@id\":\"https:\/\/www.ampouletest.com\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ISO 720 Hydrolytic Resistance of Glass Containers\/Ampoule","description":"ISO 720 for hydrolytic resistance of glass containers. Learn how Cell Instruments\u2019 GHR-01A ensures accurate, compliant results.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ampouletest.com\/sl\/iso-720-hydrolytic-resistance-of-glass-containers\/","og_locale":"sl_SI","og_type":"article","og_title":"ISO 720 Hydrolytic Resistance of Glass Containers\/Ampoule","og_description":"ISO 720 for hydrolytic resistance of glass containers. Learn how Cell Instruments\u2019 GHR-01A ensures accurate, compliant results.","og_url":"https:\/\/www.ampouletest.com\/sl\/iso-720-hydrolytic-resistance-of-glass-containers\/","og_site_name":"Ampoule Test","article_modified_time":"2026-02-02T00:15:34+00:00","og_image":[{"width":600,"height":600,"url":"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/ISO-720-Hydrolytic-Resistance-of-Glass-Ampoule-1.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.ampouletest.com\/iso-720-hydrolytic-resistance-of-glass-containers","url":"https:\/\/www.ampouletest.com\/iso-720-hydrolytic-resistance-of-glass-containers","name":"ISO 720 Hydrolytic Resistance of Glass Containers\/Ampoule","isPartOf":{"@id":"https:\/\/www.ampouletest.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.ampouletest.com\/iso-720-hydrolytic-resistance-of-glass-containers#primaryimage"},"image":{"@id":"https:\/\/www.ampouletest.com\/iso-720-hydrolytic-resistance-of-glass-containers#primaryimage"},"thumbnailUrl":"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/ISO-720-Hydrolytic-Resistance-of-Glass-Ampoule-1.webp","datePublished":"2025-06-17T07:40:00+00:00","dateModified":"2026-02-02T00:15:34+00:00","description":"ISO 720 for hydrolytic resistance of glass containers. Learn how Cell Instruments\u2019 GHR-01A ensures accurate, compliant results.","breadcrumb":{"@id":"https:\/\/www.ampouletest.com\/iso-720-hydrolytic-resistance-of-glass-containers#breadcrumb"},"inLanguage":"sl-SI","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ampouletest.com\/iso-720-hydrolytic-resistance-of-glass-containers"]}]},{"@type":"ImageObject","inLanguage":"sl-SI","@id":"https:\/\/www.ampouletest.com\/iso-720-hydrolytic-resistance-of-glass-containers#primaryimage","url":"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/ISO-720-Hydrolytic-Resistance-of-Glass-Ampoule-1.webp","contentUrl":"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/06\/ISO-720-Hydrolytic-Resistance-of-Glass-Ampoule-1.webp"},{"@type":"BreadcrumbList","@id":"https:\/\/www.ampouletest.com\/iso-720-hydrolytic-resistance-of-glass-containers#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.ampouletest.com\/"},{"@type":"ListItem","position":2,"name":"ISO 720"}]},{"@type":"WebSite","@id":"https:\/\/www.ampouletest.com\/#website","url":"https:\/\/www.ampouletest.com\/","name":"Softgel Test","description":"Ampoule Test Solutions","publisher":{"@id":"https:\/\/www.ampouletest.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.ampouletest.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"sl-SI"},{"@type":"Organization","@id":"https:\/\/www.ampouletest.com\/#organization","name":"Softgel Test","url":"https:\/\/www.ampouletest.com\/","logo":{"@type":"ImageObject","inLanguage":"sl-SI","@id":"https:\/\/www.ampouletest.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/01\/Softgel-Test-Logo.webp","contentUrl":"https:\/\/www.ampouletest.com\/wp-content\/uploads\/2025\/01\/Softgel-Test-Logo.webp","width":836,"height":238,"caption":"Softgel Test"},"image":{"@id":"https:\/\/www.ampouletest.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.ampouletest.com\/sl\/wp-json\/wp\/v2\/pages\/433","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ampouletest.com\/sl\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.ampouletest.com\/sl\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.ampouletest.com\/sl\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ampouletest.com\/sl\/wp-json\/wp\/v2\/comments?post=433"}],"version-history":[{"count":5,"href":"https:\/\/www.ampouletest.com\/sl\/wp-json\/wp\/v2\/pages\/433\/revisions"}],"predecessor-version":[{"id":668,"href":"https:\/\/www.ampouletest.com\/sl\/wp-json\/wp\/v2\/pages\/433\/revisions\/668"}],"wp:attachment":[{"href":"https:\/\/www.ampouletest.com\/sl\/wp-json\/wp\/v2\/media?parent=433"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}